SPECIFICATIONS:
Single/Dual Zone Microcontroller Module (LPU-303).
Operating Power Requirements:
Lightening Protection:
- Gas Discharge Devices on all Inputs/Outputs & Communication line.
Alarm Outputs:
- Intrusion and Line monitoring output for each zone.
- Dry contact relays with N.O. and N.C. contacts rated 1A @ 12VDC.
- Alarm transmission via Ethernet TCP/IP.
- Alarm transmission via RS-485 Protocol.
Alarm Indicators:
- Power Status LED.
- Alarm Relay Status LED.
- Tamper Indication LED.
Connector:
F type Coax connection Sensor Cable Inputs for each zone.
Enclosure:
- NEMA 4, IP-65
- 9.5" x 7.5" x 2.75” (24cm x 19.5cm x 7.0cm)
- Weight: 2.2 lbs (1Kg)
Environment:
- Operating Temperature: - 40°F to 176°F
(-40°C to 80°C)
- Relative Humidity up to 98% non-condensing.
Sensor Cable & Accessories:
- Maximum length per zone: 1000ft (305m).
- Steel mash outer skin
- Diameter: 0.197” (5mm).
- Color: Silver
- UV resistant cable ties (610 per Zone)
Options:
- Lantronix: Micro100 Ethernet Connection – TCP/IP Protocol.
- RS485: Intrudalert 5500 Protocol.
- VX-25: Weather Compensation Unit (for Multi-Zone Installation).
- Armored Conduit: Vandal Resistant.
- Audio jack module.
|