{"id":790,"date":"2020-02-18T09:34:07","date_gmt":"2020-02-18T09:34:07","guid":{"rendered":"http:\/\/box5154.temp.domains\/~rbteccom\/?page_id=790"},"modified":"2024-02-27T10:56:20","modified_gmt":"2024-02-27T15:56:20","slug":"perguntas-frequentes-sensor-montado-em-cerca-ironclad","status":"publish","type":"page","link":"https:\/\/www.rbtec.com\/pt\/frequently-asked-questions-ironclad-fence-mounted-sensor\/","title":{"rendered":"Perguntas frequentes IRONCLAD Fence Sensor"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><div      class=\"vc_row wpb_row section vc_row-fluid  grid_section\" style='background-color:#ffffff; padding-top:45px; padding-bottom:45px; text-align:left;'><div class=\" section_inner clearfix\"><div class='section_inner_margin clearfix'><div class=\"wpb_column vc_column_container vc_col-sm-6\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h1 style=\"text-align: center;\">Demo About the IRONCLAD Fence Mounted Sensor<\/h1>\n\n\t\t<\/div> \n\t<\/div> \t<div class=\"vc_empty_space\"  style=\"height: 25px\" ><span\n\t\t\tclass=\"vc_empty_space_inner\">\n\t\t\t<span class=\"empty_space_image\"  ><\/span>\n\t\t<\/span><\/div>\n\n\n\t<div class=\"wpb_video_widget wpb_content_element vc_clearfix   vc_custom_1702656886239 vc_video-aspect-ratio-169 vc_video-el-width-100 vc_video-align-center\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t\n\t\t\t<div class=\"wpb_video_wrapper\"><iframe title=\"RBtec IRONCLAD Demonstration - Perimeter Protection System for Fences - Perimeter Security System\" width=\"500\" height=\"281\" src=\"https:\/\/www.youtube.com\/embed\/e_bFGvZaiWE?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/div>\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><div class=\"wpb_column vc_column_container vc_col-sm-6\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h1 style=\"text-align: center;\">Detection Algorithm Demonstration<\/h1>\n\n\t\t<\/div> \n\t<\/div> \t<div class=\"vc_empty_space\"  style=\"height: 25px\" ><span\n\t\t\tclass=\"vc_empty_space_inner\">\n\t\t\t<span class=\"empty_space_image\"  ><\/span>\n\t\t<\/span><\/div>\n\n\n\t<div class=\"wpb_video_widget wpb_content_element vc_clearfix   vc_custom_1702656881232 vc_video-aspect-ratio-169 vc_video-el-width-100 vc_video-align-center\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t\n\t\t\t<div class=\"wpb_video_wrapper\"><iframe title=\"IRONCLAD Fence Alarm System DEMO for Perimeter Intrusion Detection\" width=\"500\" height=\"281\" src=\"https:\/\/www.youtube.com\/embed\/mr8uUl2cIJQ?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/div>\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><\/div><\/div><\/div><div      class=\"vc_row wpb_row section vc_row-fluid  grid_section\" style='background-color:#ffffff; padding-top:45px; padding-bottom:45px; text-align:left;'><div class=\" section_inner clearfix\"><div class='section_inner_margin clearfix'><div class=\"wpb_column vc_column_container vc_col-sm-6 vc_col-has-fill\"><div class=\"vc_column-inner vc_custom_1665153406179\"><div class=\"wpb_wrapper\"><div class=\"qode-accordion-holder clearfix qode-toggle qode-initial \">\n\t<h4 class=\"clearfix qode-title-holder\">\n<span class=\"qode-tab-title\">\n\t    <span class=\"qode-tab-title-inner\">\n        Where to do I connect the IRONCLAD system?    <\/span>\n<\/span>\n<span class=\"qode-accordion-mark\">\n    <span class=\"qode-accordion-mark-icon\">\n        <span class=\"icon_plus\"><\/span>\n        <span class=\"icon_minus-06\"><\/span>\n    <\/span>\n<\/span>\n<\/h4>\n<div  class=\"qode-accordion-content \" >\n    <div class=\"qode-accordion-content-inner\">\n        \n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<p>Each LPU analyzer\/processor has 2 or 4 dry contact relay alarm outputs NO\/NC, one per zone. Those outputs can be connected to ANY alarm system, CCTV system, access control, or any other system that can accept dry contact relay input, such as sirens, strobe lights, and even fire alarms.<\/p>\n\n\t\t<\/div> \n\t<\/div>     <\/div>\n<\/div><h4 class=\"clearfix qode-title-holder\">\n<span class=\"qode-tab-title\">\n\t    <span class=\"qode-tab-title-inner\">\n        What length of fences can i protect with the IRONCLAD?    <\/span>\n<\/span>\n<span class=\"qode-accordion-mark\">\n    <span class=\"qode-accordion-mark-icon\">\n        <span class=\"icon_plus\"><\/span>\n        <span class=\"icon_minus-06\"><\/span>\n    <\/span>\n<\/span>\n<\/h4>\n<div  class=\"qode-accordion-content \" >\n    <div class=\"qode-accordion-content-inner\">\n        \n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<p>The IRONCLAD sensor cable is sold in spools\/rolls of 250ft (75m), 500ft (150m), and 1000ft (300m).<br \/>\nEach processor can monitor up to 2 zones\/spools, which means the largest perimeter that can be covered with <strong>one<\/strong>\u00a0kit is 2000ft (600m).<br \/>\nTo cover a larger perimeter, multiple kits can be combined. Using various systems allows for covering the whole fence line.<br \/>\nBelow is a diagram of multiple 2-zone standalone kits combined to cover a larger perimeter.<\/p>\n\n\t\t<\/div> \n\t<\/div> \t<div class=\"vc_empty_space\"  style=\"height: 25px\" ><span\n\t\t\tclass=\"vc_empty_space_inner\">\n\t\t\t<span class=\"empty_space_image\"  ><\/span>\n\t\t<\/span><\/div>\n\n\n\t<div class=\"wpb_single_image wpb_content_element vc_align_center\">\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t\n\t\t\t<div class=\"vc_single_image-wrapper   vc_box_border_grey\"><img decoding=\"async\" class=\"vc_single_image-img \" src=\"https:\/\/www.rbtec.com\/wp-content\/uploads\/2020\/02\/4-Zone-Layout--550x600.jpg\" width=\"550\" height=\"600\" alt=\"4 Zone Layout\" title=\"4 Zone Layout\" \/><\/div>\n\t\t<\/div>\n\t<\/div>\n    <\/div>\n<\/div><h4 class=\"clearfix qode-title-holder\">\n<span class=\"qode-tab-title\">\n\t    <span class=\"qode-tab-title-inner\">\n        Can I adjust the sensitivity of the IRONCLAD Fence Alarm System?    <\/span>\n<\/span>\n<span class=\"qode-accordion-mark\">\n    <span class=\"qode-accordion-mark-icon\">\n        <span class=\"icon_plus\"><\/span>\n        <span class=\"icon_minus-06\"><\/span>\n    <\/span>\n<\/span>\n<\/h4>\n<div  class=\"qode-accordion-content \" >\n    <div class=\"qode-accordion-content-inner\">\n        \n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<p>Absolutely. The system&#8217;s sensitivity can be adjusted manually on the LPU (Local Processor Unit) for 20 sensitivity levels and through the calibration software for 500 sensitivity levels. This ensures that the system is finely tuned to your specific security needs. There is no need for special tools or any knowledge.<\/p>\n\n\t\t<\/div> \n\t<\/div>     <\/div>\n<\/div><h4 class=\"clearfix qode-title-holder\">\n<span class=\"qode-tab-title\">\n\t    <span class=\"qode-tab-title-inner\">\n        Does the system need any calibration before I can use it?    <\/span>\n<\/span>\n<span class=\"qode-accordion-mark\">\n    <span class=\"qode-accordion-mark-icon\">\n        <span class=\"icon_plus\"><\/span>\n        <span class=\"icon_minus-06\"><\/span>\n    <\/span>\n<\/span>\n<\/h4>\n<div  class=\"qode-accordion-content \" >\n    <div class=\"qode-accordion-content-inner\">\n        \n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<p>No, the IRONCLAD system self-calibrates a baseline. Once that&#8217;s set, only sensitivity adjustment is needed. The system is a plug-and-play system that requires power, sensor inputs, and relay outputs and works!<\/p>\n\n\t\t<\/div> \n\t<\/div>     <\/div>\n<\/div><h4 class=\"clearfix qode-title-holder\">\n<span class=\"qode-tab-title\">\n\t    <span class=\"qode-tab-title-inner\">\n        Does wind or rain can cause false alarms?    <\/span>\n<\/span>\n<span class=\"qode-accordion-mark\">\n    <span class=\"qode-accordion-mark-icon\">\n        <span class=\"icon_plus\"><\/span>\n        <span class=\"icon_minus-06\"><\/span>\n    <\/span>\n<\/span>\n<\/h4>\n<div  class=\"qode-accordion-content \" >\n    <div class=\"qode-accordion-content-inner\">\n        \n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<p><strong>The IRONCLAD system works: It detects only sharp frequency vibrations <\/strong>generated by cutting, climbing, or jumping the fence. Vibrations caused by wind, rain, and small animals are usually long-wave, low-frequency vibrations that the system would not pick up.<\/p>\n<p>&nbsp;<\/p>\n<p>It&#8217;s the difference between tapping or climbing the fence, which will get detected, vs. pushing on the fence like the wind that won&#8217;t.<\/p>\n<p>&nbsp;<\/p>\n<p>On top of that, we have an optional weather station that can feed the analyzer with real-time information about the weather around it and compensate for the wind and rain to give an even higher level of assurance of filtering out false alarms.<\/p>\n\n\t\t<\/div> \n\t<\/div>     <\/div>\n<\/div><h4 class=\"clearfix qode-title-holder\">\n<span class=\"qode-tab-title\">\n\t    <span class=\"qode-tab-title-inner\">\n        What type of fences is the IRONCLAD compatible with?    <\/span>\n<\/span>\n<span class=\"qode-accordion-mark\">\n    <span class=\"qode-accordion-mark-icon\">\n        <span class=\"icon_plus\"><\/span>\n        <span class=\"icon_minus-06\"><\/span>\n    <\/span>\n<\/span>\n<\/h4>\n<div  class=\"qode-accordion-content \" >\n    <div class=\"qode-accordion-content-inner\">\n        \n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<p>The IRONCLAD can be installed on most fence types, including chain link, welded mesh, and palisade. The fence should be in good condition, fully intact, straight, under tension, and free of obstructions for optimal performance. For Rigid metal fences, see the <a href=\"https:\/\/www.rbtec.com\/perimeter-sensors-and-underground-protection\/fence-intrusion-detection-products\/micalertmicrophonicsensorcable\/\">MICALERT Microphonic Rigid Fence Sensor Cable<\/a><\/p>\n\n\t\t<\/div> \n\t<\/div>     <\/div>\n<\/div><h4 class=\"clearfix qode-title-holder\">\n<span class=\"qode-tab-title\">\n\t    <span class=\"qode-tab-title-inner\">\n        What should I do if I encounter false alarms or system noise?    <\/span>\n<\/span>\n<span class=\"qode-accordion-mark\">\n    <span class=\"qode-accordion-mark-icon\">\n        <span class=\"icon_plus\"><\/span>\n        <span class=\"icon_minus-06\"><\/span>\n    <\/span>\n<\/span>\n<\/h4>\n<div  class=\"qode-accordion-content \" >\n    <div class=\"qode-accordion-content-inner\">\n        \n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<p>First, ensure the sensor cable is installed correctly with no slack or air gaps. Check for loose connections, ensure the fence is free from external noise sources, and add ground to the negative of the DC power. You can adjust the system&#8217;s sensitivity or seek professional assistance if issues persist.<\/p>\n\n\t\t<\/div> \n\t<\/div>     <\/div>\n<\/div><\/div><\/div><\/div><\/div><div class=\"wpb_column vc_column_container vc_col-sm-6 vc_col-has-fill\"><div class=\"vc_column-inner vc_custom_1665153415371\"><div class=\"wpb_wrapper\"><div class=\"qode-accordion-holder clearfix qode-toggle qode-initial \">\n\t<h4 class=\"clearfix qode-title-holder\">\n<span class=\"qode-tab-title\">\n\t    <span class=\"qode-tab-title-inner\">\n        Where can I buy the IRONCLAD Fence Mounted Sensor and How do i choose the right parts?    <\/span>\n<\/span>\n<span class=\"qode-accordion-mark\">\n    <span class=\"qode-accordion-mark-icon\">\n        <span class=\"icon_plus\"><\/span>\n        <span class=\"icon_minus-06\"><\/span>\n    <\/span>\n<\/span>\n<\/h4>\n<div  class=\"qode-accordion-content \" >\n    <div class=\"qode-accordion-content-inner\">\n        \n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h2>To download the code tables or other materials you can see more at our download page: <a  itemprop=\"url\" href=\"\/documentation\" target=\"_self\"  class=\"qbutton  default\" style=\"\">Click Here<\/a><\/h2>\n<hr \/>\n<p style=\"text-align: left;\"><a class=\"qbutton medium default\" href=\"\/ironclad-design-guide-ver3\/\" rel=\"noopener noreferrer\">Site &amp; System Design Manual<\/a><\/p>\n<p>&nbsp;<\/p>\n<p><a class=\"qbutton medium default\" href=\"\/contact-us\/\" target=\"_self\" rel=\"noopener noreferrer\">Where to buy?<\/a><\/p>\n\n\t\t<\/div> \n\t<\/div>     <\/div>\n<\/div><h4 class=\"clearfix qode-title-holder\">\n<span class=\"qode-tab-title\">\n\t    <span class=\"qode-tab-title-inner\">\n        Can the cable be installed on Sliding gate or Swing gate?    <\/span>\n<\/span>\n<span class=\"qode-accordion-mark\">\n    <span class=\"qode-accordion-mark-icon\">\n        <span class=\"icon_plus\"><\/span>\n        <span class=\"icon_minus-06\"><\/span>\n    <\/span>\n<\/span>\n<\/h4>\n<div  class=\"qode-accordion-content \" >\n    <div class=\"qode-accordion-content-inner\">\n        \t<div class=\"vc_empty_space\"  style=\"height: 25px\" ><span\n\t\t\tclass=\"vc_empty_space_inner\">\n\t\t\t<span class=\"empty_space_image\"  ><\/span>\n\t\t<\/span><\/div>\n\n<div class=\"vc_text_separator wpb_content_element full separator_align_center\"><div style=''><span>Option 1 - Swing gate with NO conduit<\/span><\/div><\/div>\n\n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<p>Protection of an emergency gate or rarely used can be done by using the gate connector (sold separately), the connector will be connected to the cable at the opening point of the gate to allow the gate to be opened or closed. <strong>It&#8217;s not recommended to use this connection on often used gates.<\/strong><\/p>\n\n\t\t<\/div> \n\t<\/div> \t<div class=\"vc_empty_space\"  style=\"height: 25px\" ><span\n\t\t\tclass=\"vc_empty_space_inner\">\n\t\t\t<span class=\"empty_space_image\"  ><\/span>\n\t\t<\/span><\/div>\n\n\n\t<div class=\"wpb_single_image wpb_content_element vc_align_center\">\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t\n\t\t\t<a class=\"qode-prettyphoto qode-single-image-pretty-photo\" data-rel=\"prettyPhoto[rel-790-61038620]\" href=\"https:\/\/www.rbtec.com\/wp-content\/uploads\/2020\/02\/Gate-connector-drawing.jpg\" target=\"_self\"><div class=\"vc_single_image-wrapper   vc_box_border_grey\"><img decoding=\"async\" class=\"vc_single_image-img \" src=\"https:\/\/www.rbtec.com\/wp-content\/uploads\/2020\/02\/Gate-connector-drawing-700x450.jpg\" width=\"700\" height=\"450\" alt=\"Gate connector drawing\" title=\"Gate connector drawing\" \/><\/div><\/a>\n\t\t<\/div>\n\t<\/div>\n\t<div class=\"vc_empty_space\"  style=\"height: 25px\" ><span\n\t\t\tclass=\"vc_empty_space_inner\">\n\t\t\t<span class=\"empty_space_image\"  ><\/span>\n\t\t<\/span><\/div>\n\n<div class=\"vc_text_separator wpb_content_element full separator_align_center\"><div style=''><span>Option 2 - Swing gate with WITH conduit<\/span><\/div><\/div>\n\n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<p>A single or double swing gate is protected in the same method.<br \/>\nThe sensor cable is looped on the gate, then connected to a junction box RB-RBMCTXT and spliced with an RG6 direct burial to go under the gate, on the other end, it is spliced back to a sensor cable and looped on the other side of the gate.<br \/>\nOn the hinges, enough sensors need to be left to allow it to move freely with the gate opening and closing so the cable won&#8217;t stretch or bend sharply.<\/p>\n\n\t\t<\/div> \n\t<\/div> \t<div class=\"vc_empty_space\"  style=\"height: 25px\" ><span\n\t\t\tclass=\"vc_empty_space_inner\">\n\t\t\t<span class=\"empty_space_image\"  ><\/span>\n\t\t<\/span><\/div>\n\n\n\t<div class=\"wpb_single_image wpb_content_element vc_align_center\">\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t\n\t\t\t<a class=\"qode-prettyphoto qode-single-image-pretty-photo\" data-rel=\"prettyPhoto[rel-790-2295472408]\" href=\"https:\/\/www.rbtec.com\/wp-content\/uploads\/2020\/02\/Gate-protection-drawing.jpg\" target=\"_self\"><div class=\"vc_single_image-wrapper   vc_box_border_grey\"><img decoding=\"async\" class=\"vc_single_image-img \" src=\"https:\/\/www.rbtec.com\/wp-content\/uploads\/2020\/02\/Gate-protection-drawing-700x450.jpg\" width=\"700\" height=\"450\" alt=\"Gate protection drawing\" title=\"Gate protection drawing\" \/><\/div><\/a>\n\t\t<\/div>\n\t<\/div>\n\t<div class=\"vc_empty_space\"  style=\"height: 25px\" ><span\n\t\t\tclass=\"vc_empty_space_inner\">\n\t\t\t<span class=\"empty_space_image\"  ><\/span>\n\t\t<\/span><\/div>\n\n<div class=\"vc_text_separator wpb_content_element full separator_align_center\"><div style=''><span>Option 3 - Sliding gate with WITH conduit<\/span><\/div><\/div>\n\n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h3 style=\"text-align: left;\"><span style=\"text-decoration: underline;\"><strong>Sliding gates can be treated in 2 ways<\/strong><\/span><\/h3>\n<p style=\"text-align: left;\">1. Bypass the gate and put a motion sensor across the gate to protect the crossing.<br \/>\n2. Use the RBtec sliding gate kit. A sliding gate is designed for light to medium traffic gates. Heavily used gates with hundreds of openings a day must be protected with another technology, such as a camera or motion sensor.<\/p>\n\n\t\t<\/div> \n\t<\/div> \t<div class=\"vc_empty_space\"  style=\"height: 25px\" ><span\n\t\t\tclass=\"vc_empty_space_inner\">\n\t\t\t<span class=\"empty_space_image\"  ><\/span>\n\t\t<\/span><\/div>\n\n\n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h3>Video showing the Operation of the Sliding Gate Kit<\/h3>\n\n\t\t<\/div> \n\t<\/div> \t<div class=\"vc_empty_space\"  style=\"height: 25px\" ><span\n\t\t\tclass=\"vc_empty_space_inner\">\n\t\t\t<span class=\"empty_space_image\"  ><\/span>\n\t\t<\/span><\/div>\n\n\n\t<div class=\"wpb_video_widget wpb_content_element vc_clearfix   vc_video-aspect-ratio-169 vc_video-el-width-70 vc_video-align-center\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t\n\t\t\t<div class=\"wpb_video_wrapper\"><iframe title=\"Protection for Sliding Gates with the RBtec Sliding Kit - Rolling gate protection\" width=\"500\" height=\"281\" src=\"https:\/\/www.youtube.com\/embed\/Vsh79_EVuRY?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/div>\n\t\t<\/div>\n\t<\/div>\n\t<div class=\"vc_empty_space\"  style=\"height: 25px\" ><span\n\t\t\tclass=\"vc_empty_space_inner\">\n\t\t\t<span class=\"empty_space_image\"  ><\/span>\n\t\t<\/span><\/div>\n\n\n\t<div class=\"wpb_single_image wpb_content_element vc_align_center\">\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t\n\t\t\t<a class=\"qode-prettyphoto qode-single-image-pretty-photo\" data-rel=\"prettyPhoto[rel-790-2019231941]\" href=\"https:\/\/www.rbtec.com\/wp-content\/uploads\/2020\/02\/Sliding-gate-end-of-zone-779x1024.jpg\" target=\"_self\"><div class=\"vc_single_image-wrapper   vc_box_border_grey\"><img decoding=\"async\" width=\"779\" height=\"1024\" src=\"https:\/\/www.rbtec.com\/wp-content\/uploads\/2020\/02\/Sliding-gate-end-of-zone-779x1024.jpg\" class=\"vc_single_image-img attachment-large\" alt=\"\" title=\"Sliding gate end of zone\" srcset=\"https:\/\/www.rbtec.com\/wp-content\/uploads\/2020\/02\/Sliding-gate-end-of-zone-779x1024.jpg 779w, https:\/\/www.rbtec.com\/wp-content\/uploads\/2020\/02\/Sliding-gate-end-of-zone-228x300.jpg 228w, https:\/\/www.rbtec.com\/wp-content\/uploads\/2020\/02\/Sliding-gate-end-of-zone-768x1009.jpg 768w, https:\/\/www.rbtec.com\/wp-content\/uploads\/2020\/02\/Sliding-gate-end-of-zone-700x920.jpg 700w, https:\/\/www.rbtec.com\/wp-content\/uploads\/2020\/02\/Sliding-gate-end-of-zone.jpg 913w\" sizes=\"(max-width: 779px) 100vw, 779px\" \/><\/div><\/a>\n\t\t<\/div>\n\t<\/div>\n\t<div class=\"vc_empty_space\"  style=\"height: 25px\" ><span\n\t\t\tclass=\"vc_empty_space_inner\">\n\t\t\t<span class=\"empty_space_image\"  ><\/span>\n\t\t<\/span><\/div>\n\n    <\/div>\n<\/div><h4 class=\"clearfix qode-title-holder\">\n<span class=\"qode-tab-title\">\n\t    <span class=\"qode-tab-title-inner\">\n        How long does it take to install the IRONCLAD on a fence?    <\/span>\n<\/span>\n<span class=\"qode-accordion-mark\">\n    <span class=\"qode-accordion-mark-icon\">\n        <span class=\"icon_plus\"><\/span>\n        <span class=\"icon_minus-06\"><\/span>\n    <\/span>\n<\/span>\n<\/h4>\n<div  class=\"qode-accordion-content \" >\n    <div class=\"qode-accordion-content-inner\">\n        \n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<p>Typically, attaching the sensor cable takes about 1 hour per 300 feet (100 meters). It&#8217;s crucial to follow the detailed installation guide for proper setup. Please log in to download the IRONCLAD <a href=\"https:\/\/www.rbtec.com\/private-downloads\/\">Installation Manual<\/a><\/p>\n\n\t\t<\/div> \n\t<\/div>     <\/div>\n<\/div><h4 class=\"clearfix qode-title-holder\">\n<span class=\"qode-tab-title\">\n\t    <span class=\"qode-tab-title-inner\">\n        Can the cable be shortened\/cut\/spliced?    <\/span>\n<\/span>\n<span class=\"qode-accordion-mark\">\n    <span class=\"qode-accordion-mark-icon\">\n        <span class=\"icon_plus\"><\/span>\n        <span class=\"icon_minus-06\"><\/span>\n    <\/span>\n<\/span>\n<\/h4>\n<div  class=\"qode-accordion-content \" >\n    <div class=\"qode-accordion-content-inner\">\n        \n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<p><strong>Yes! <\/strong>The cable can be cut to fit the fence size. Although the fence sensor cable is sold in fixed sizes it can be cut into any desired length. The cable is a 2 conductor copper wire.<\/p>\n\n\t\t<\/div> \n\t<\/div>     <\/div>\n<\/div><h4 class=\"clearfix qode-title-holder\">\n<span class=\"qode-tab-title\">\n\t    <span class=\"qode-tab-title-inner\">\n        Do we need to change to another cable to bypass a gate?    <\/span>\n<\/span>\n<span class=\"qode-accordion-mark\">\n    <span class=\"qode-accordion-mark-icon\">\n        <span class=\"icon_plus\"><\/span>\n        <span class=\"icon_minus-06\"><\/span>\n    <\/span>\n<\/span>\n<\/h4>\n<div  class=\"qode-accordion-content \" >\n    <div class=\"qode-accordion-content-inner\">\n        \n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<p>If you would like to bypass the gate entirely and not use the RBtec gate connector, then using direct burial RG6 as a non-sensitive conduit is recommended.<\/p>\n\n\t\t<\/div> \n\t<\/div>     <\/div>\n<\/div><h4 class=\"clearfix qode-title-holder\">\n<span class=\"qode-tab-title\">\n\t    <span class=\"qode-tab-title-inner\">\n        If the cable got cut can it repaired?    <\/span>\n<\/span>\n<span class=\"qode-accordion-mark\">\n    <span class=\"qode-accordion-mark-icon\">\n        <span class=\"icon_plus\"><\/span>\n        <span class=\"icon_minus-06\"><\/span>\n    <\/span>\n<\/span>\n<\/h4>\n<div  class=\"qode-accordion-content \" >\n    <div class=\"qode-accordion-content-inner\">\n        \n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<p><strong>Yes!<\/strong> Repairing the cable is a 30 second process. RBtec offers a repair kit (RB-RBMCTXT) that bridges the cut in a weatherproof method to maintain the system&#8217;s performance.<br \/>\nThe repair box is installed at the cut point, the sensor cable connects to screw terminals on both sides of the repair box, and the system is back up and running.<\/p>\n\n\t\t<\/div> \n\t<\/div>     <\/div>\n<\/div><h4 class=\"clearfix qode-title-holder\">\n<span class=\"qode-tab-title\">\n\t    <span class=\"qode-tab-title-inner\">\n        If the cable got cut can it repaired?    <\/span>\n<\/span>\n<span class=\"qode-accordion-mark\">\n    <span class=\"qode-accordion-mark-icon\">\n        <span class=\"icon_plus\"><\/span>\n        <span class=\"icon_minus-06\"><\/span>\n    <\/span>\n<\/span>\n<\/h4>\n<div  class=\"qode-accordion-content \" >\n    <div class=\"qode-accordion-content-inner\">\n        \n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<p><strong>Yes!<\/strong> Repairing the cable is a 30 second process. RBtec offers a repair kit (RB-RBMCTXT) that bridges the cut in a weatherproof method to maintain the system&#8217;s performance.<br \/>\nThe repair box is installed at the cut point, the sensor cable connects to screw terminals on both sides of the repair box, and the system is back up and running.<\/p>\n\n\t\t<\/div> \n\t<\/div>     <\/div>\n<\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><div      class=\"vc_row wpb_row section vc_row-fluid  grid_section\" style='background-color:#ffffff; padding-top:45px; padding-bottom:45px; text-align:left;'><div class=\" section_inner clearfix\"><div class='section_inner_margin clearfix'><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h1 style=\"text-align: center;\">Basic Guide to Troubleshooting False Alarms in IRONCLAD Security Systems<\/h1>\n\n\t\t<\/div> \n\t<\/div> \n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<p>Many times, false alarms in security systems like IRONCLAD are not merely due to sensitivity settings but are often caused by technical issues with the system or its surroundings. Lowering the sensitivity frequently doesn&#8217;t solve the underlying issue but merely masks it. Therefore, it&#8217;s crucial to systematically investigate and address potential technical and environmental factors contributing to false alarms.<\/p>\n<ol>\n<li><strong>Check Fence Condition<\/strong>: Ensure the fence is in good condition &#8211; fully intact, straight, under tension, and free of obstructions. Loose signs or debris can cause false alarms.<\/li>\n<li><strong>Inspect Sensor Cable Installation<\/strong>: Verify the sensor cable is properly installed \u2013 it should be attached mid-height, run parallel to the ground, and have no slack. Ensure ties are secure but not over-tightened.<\/li>\n<li><strong>Examine Cable and Connections<\/strong>: Look for any damaged or loosely connected sections of the sensor cable. Ensure all end-of-line terminations are correctly installed as per the manual.<\/li>\n<li><strong>Measure Sensor Wire Resistance<\/strong>: Disconnect the sensor wire from the LPU and measure its resistance. The proper resistance should match the end-of-line resistor, which is typically 1M ohm. A discrepancy indicates issues with the sensor wire or connections.<\/li>\n<li><strong>Review Sensor Calibration<\/strong>: Check if the sensor sensitivity is set appropriately. Overly sensitive settings can lead to false alarms. Use the LPU-400 calibration software to adjust if necessary.<\/li>\n<li><strong>Test Power Source<\/strong>: Check the power source for noise. Ground the negative of the DC voltage to eliminate noise from the power source. If this doesn&#8217;t resolve the issue, test the system with a 12V DC battery. If using a battery solves the problem, consider permanently grounding or replacing the power supply.<\/li>\n<li><strong>Environmental Factors<\/strong>: Assess the fence&#8217;s surroundings for elements that could trigger false alarms, such as loose signs, items hitting the fence during windy conditions, metal-to-metal rattling, heavy branches slapping the fence, loose barb wires, cables, or any other items hung on or near the fence. These factors can physically interact with the fence and contribute to false alarms, especially in adverse weather conditions.<\/li>\n<li><strong>Periodic System Testing<\/strong>: Conduct regular system tests to ensure proper operation and adjust sensitivity levels as needed.<\/li>\n<\/ol>\n<p>This comprehensive approach should effectively help you identify and address the source of false alarms in your IRONCLAD system.<\/p>\n\n\t\t<\/div> \n\t<\/div> \t<div class=\"vc_empty_space\"  style=\"height: 25px\" ><span\n\t\t\tclass=\"vc_empty_space_inner\">\n\t\t\t<span class=\"empty_space_image\"  ><\/span>\n\t\t<\/span><\/div>\n\n\n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h2 style=\"text-align: center;\">Have any other questions? please contact us at\u00a0<a href=\"mailto:Info@rbtec.com\">Info@rbtec.com<\/a><br \/>\nFor tech support call +1-480-442-3411<\/h2>\n\n\t\t<\/div> \n\t<\/div> <\/div><\/div><\/div><\/div><\/div><\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"Demonstra\u00e7\u00e3o Sobre o Algoritmo de Detec\u00e7\u00e3o do Sensor Montado em Cerca IRONCLAD Demonstra\u00e7\u00e3o Onde devo conectar o sistema IRONCLAD? Cada analisador\/processador LPU possui 2 ou 4 sa\u00eddas de alarme de rel\u00e9 de contato seco NA\/NC, uma por zona. Essas sa\u00eddas podem ser conectadas a QUALQUER sistema de alarme, sistema CCTV,...","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"full_width.php","meta":{"footnotes":""},"class_list":["post-790","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.0 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>IRONCLAD Fence Mounted Sensor - Frequently Asked Questions<\/title>\n<meta name=\"description\" content=\"Frequently asked questions about the IRONCLAD Fence Mounted Vibration Sensor, how to install and where can you buy the IRONCLAD fence alarm system.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.rbtec.com\/pt\/perguntas-frequentes-sensor-montado-em-cerca-ironclad\/\" \/>\n<meta property=\"og:locale\" content=\"pt_BR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"IRONCLAD Fence Mounted Sensor - Frequently Asked Questions\" \/>\n<meta property=\"og:description\" content=\"Frequently asked questions about the IRONCLAD Fence Mounted Vibration Sensor, how to install and where can you buy the IRONCLAD fence alarm system.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.rbtec.com\/pt\/perguntas-frequentes-sensor-montado-em-cerca-ironclad\/\" \/>\n<meta property=\"og:site_name\" content=\"RBtec Perimeter Security Systems\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/perimeterintrusiondetection\/\" \/>\n<meta property=\"article:modified_time\" content=\"2024-02-27T15:56:20+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.rbtec.com\/frequently-asked-questions-ironclad-fence-mounted-sensor\/\",\"url\":\"https:\/\/www.rbtec.com\/frequently-asked-questions-ironclad-fence-mounted-sensor\/\",\"name\":\"IRONCLAD Fence Mounted Sensor - Frequently Asked Questions\",\"isPartOf\":{\"@id\":\"https:\/\/www.rbtec.com\/#website\"},\"datePublished\":\"2020-02-18T09:34:07+00:00\",\"dateModified\":\"2024-02-27T15:56:20+00:00\",\"description\":\"Frequently asked questions about the IRONCLAD Fence Mounted Vibration Sensor, how to install and where can you buy the IRONCLAD fence alarm system.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.rbtec.com\/frequently-asked-questions-ironclad-fence-mounted-sensor\/#breadcrumb\"},\"inLanguage\":\"pt-BR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.rbtec.com\/frequently-asked-questions-ironclad-fence-mounted-sensor\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.rbtec.com\/frequently-asked-questions-ironclad-fence-mounted-sensor\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.rbtec.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Frequently Asked Questions IRONCLAD Fence Sensor\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.rbtec.com\/#website\",\"url\":\"https:\/\/www.rbtec.com\/\",\"name\":\"RBtec Perimeter Security Systems\",\"description\":\"Perimeter Security System PIDS\",\"publisher\":{\"@id\":\"https:\/\/www.rbtec.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.rbtec.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"pt-BR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.rbtec.com\/#organization\",\"name\":\"RBtec Perimeter Security Systems\",\"alternateName\":\"RBtec\",\"url\":\"https:\/\/www.rbtec.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-BR\",\"@id\":\"https:\/\/www.rbtec.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.rbtec.com\/wp-content\/uploads\/2020\/02\/newLogo.png\",\"contentUrl\":\"https:\/\/www.rbtec.com\/wp-content\/uploads\/2020\/02\/newLogo.png\",\"width\":299,\"height\":70,\"caption\":\"RBtec Perimeter Security Systems\"},\"image\":{\"@id\":\"https:\/\/www.rbtec.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/perimeterintrusiondetection\/\",\"https:\/\/www.linkedin.com\/company\/rbtec\/\",\"http:\/\/www.youtube.com\/@RBtec-perimeter-security\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Sensor montado em cerca IRONCLAD - Perguntas freq\u00fcentes","description":"Perguntas freq\u00fcentes sobre o sensor de vibra\u00e7\u00e3o montado em cerca IRONCLAD, como instalar e onde voc\u00ea pode comprar o sistema de alarme de cerca IRONCLAD.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.rbtec.com\/pt\/perguntas-frequentes-sensor-montado-em-cerca-ironclad\/","og_locale":"pt_BR","og_type":"article","og_title":"IRONCLAD Fence Mounted Sensor - Frequently Asked Questions","og_description":"Frequently asked questions about the IRONCLAD Fence Mounted Vibration Sensor, how to install and where can you buy the IRONCLAD fence alarm system.","og_url":"https:\/\/www.rbtec.com\/pt\/perguntas-frequentes-sensor-montado-em-cerca-ironclad\/","og_site_name":"RBtec Perimeter Security Systems","article_publisher":"https:\/\/www.facebook.com\/perimeterintrusiondetection\/","article_modified_time":"2024-02-27T15:56:20+00:00","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.rbtec.com\/frequently-asked-questions-ironclad-fence-mounted-sensor\/","url":"https:\/\/www.rbtec.com\/frequently-asked-questions-ironclad-fence-mounted-sensor\/","name":"Sensor montado em cerca IRONCLAD - Perguntas freq\u00fcentes","isPartOf":{"@id":"https:\/\/www.rbtec.com\/#website"},"datePublished":"2020-02-18T09:34:07+00:00","dateModified":"2024-02-27T15:56:20+00:00","description":"Perguntas freq\u00fcentes sobre o sensor de vibra\u00e7\u00e3o montado em cerca IRONCLAD, como instalar e onde voc\u00ea pode comprar o sistema de alarme de cerca IRONCLAD.","breadcrumb":{"@id":"https:\/\/www.rbtec.com\/frequently-asked-questions-ironclad-fence-mounted-sensor\/#breadcrumb"},"inLanguage":"pt-BR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.rbtec.com\/frequently-asked-questions-ironclad-fence-mounted-sensor\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.rbtec.com\/frequently-asked-questions-ironclad-fence-mounted-sensor\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.rbtec.com\/"},{"@type":"ListItem","position":2,"name":"Frequently Asked Questions IRONCLAD Fence Sensor"}]},{"@type":"WebSite","@id":"https:\/\/www.rbtec.com\/#website","url":"https:\/\/www.rbtec.com\/","name":"RBtec Sistemas de Prote\u00e7\u00e3o Perimetral","description":"Sistema de seguran\u00e7a de per\u00edmetro PIDS","publisher":{"@id":"https:\/\/www.rbtec.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.rbtec.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"pt-BR"},{"@type":"Organization","@id":"https:\/\/www.rbtec.com\/#organization","name":"RBtec Sistemas de Prote\u00e7\u00e3o Perimetral","alternateName":"RBtec","url":"https:\/\/www.rbtec.com\/","logo":{"@type":"ImageObject","inLanguage":"pt-BR","@id":"https:\/\/www.rbtec.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.rbtec.com\/wp-content\/uploads\/2020\/02\/newLogo.png","contentUrl":"https:\/\/www.rbtec.com\/wp-content\/uploads\/2020\/02\/newLogo.png","width":299,"height":70,"caption":"RBtec Perimeter Security Systems"},"image":{"@id":"https:\/\/www.rbtec.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/perimeterintrusiondetection\/","https:\/\/www.linkedin.com\/company\/rbtec\/","http:\/\/www.youtube.com\/@RBtec-perimeter-security"]}]}},"_links":{"self":[{"href":"https:\/\/www.rbtec.com\/pt\/wp-json\/wp\/v2\/pages\/790","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.rbtec.com\/pt\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.rbtec.com\/pt\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.rbtec.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.rbtec.com\/pt\/wp-json\/wp\/v2\/comments?post=790"}],"version-history":[{"count":0,"href":"https:\/\/www.rbtec.com\/pt\/wp-json\/wp\/v2\/pages\/790\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.rbtec.com\/pt\/wp-json\/wp\/v2\/media?parent=790"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}