WallAlert壁挂式入侵检测传感器

The WallAlert protects walls and dry wall against impacts caused by intrusions attempts.

 

  • 非常适合在砖墙和石膏板上安装。
  • 即插即用–准备安装价格合理的工具包。
  • Attached directly to the wall to detect impact, breaking or cutting of the wall.
  • No training or special tools needed comes with installation manual.
  • 无校准–系统自校准。
  • Maintenance-free – 2 years warranty on the sensor cable.
  • 每个区域的22个灵敏度级别都可以通过DIP开关轻松调节。
  • 干接点继电器输出(常开或常闭),可以连接到任何报警系统/ DVR。

在您的墙上实时检测入侵者

The WallAlert Sensor cable is an ideal system for brick wall and drywall to detecting mechanical vibration transmitted along the wall as an intruder attempts to break through the wall.
It is designed to detect impacts on walls, by analyzing vibrations created during an intrusion attempt. The WallAlert is suitable for monitoring large building structures such as storage warehouses, retail sites and transportation and logistics building facades.

 

The WallAlert wall mounted intrusion detection system is a passive electronic intrusion detector system. The WallAlert Wall intrusion detection system is based on sensing types of frequencies associated with intrusion attempts while filtering ones related to non-conditions.

 

The WallAlert Wall Intrusion Detection System offers a solution for intrusion detection by the analysis of typical noise patterns made by a forced entry attempt. The system can recognize motion caused by an attempt to pass through the fence and disregard signals caused by weather conditions, preventing nuisance alarms.
该传感器设计为直接安装在没有任何导管的刚性围栏上。

The WallAlert Wall Intrusion Detection System Is the ideal solution for protecting:

  • 货仓
  • 数据中心
  • 储存区

墙壁报警系统的传感器布局为:

1.传感器电缆已预切成500ft / 152m和1000ft / 305m

2.每个处理器(分析仪)最多可以监视2个区域(线轴)

3.每个处理器的最大长度为2000ft / 600m传感器电缆,
2个1000ft / 305m区域

4.每个套件还包括:防风雨外壳中的处理器
和传感器电缆的选定长度。

5.为了覆盖更大的范围,可以选择组合
根据需要提供许多套件。

The WallAlert is Available at These Distributors.

 

在哪里买

单/双区域微控制器模块(LPU-303)。

工作电源要求: 12 – 15VDC 40mA @ 12VDC
防雷保护: 所有输入/输出和通讯线上的气体排放设备。
警报输出: 每个区域的入侵和线路监视输出。干接点继电器,常开和常闭触点额定值为1A @ 12VDC。通过RS-485协议传输警报。
警报指示灯:
电源状态LED。
警报继电器状态LED。
防拆指示LED。
接头: 每个区域的F型同轴电缆连接传感器电缆输入。
外壳: NEMA 4x,IP-66
9.5英寸x 7.5英寸x 2.75英寸(24厘米x 19.5厘米x 7.0厘米)
重量:2.2磅(1公斤)
环境: 工作温度:– 40°F至176°F(-40°C至80°C)
相对湿度高达98%,无冷凝。
传感器电缆及配件: 每个区域的最大长度:1000英尺(305m)。适用于250/500 / 1000ft(75/152 / 305m)的线轴
直径:  0.118英寸(3毫米)
颜色: 黑色
防紫外线扎带 (每个区域610)
线尾电阻卡:将室外防风雨外壳盒超声波焊接到检测传感器线上。
选项: VX-25:天气补偿单元(用于多区域安装)。