Perimeterskydd för ett Distributionscenter

Ett distributionscenter säkrade sin 1 200 m långa perimeter med IRONCLAD efter godsstöldförsök vid stängslet: fyra zoner på två processorer, installerade på några dagar utan att stoppa den dygnetruntdrivna gårdsverksamheten, med uppkoppling mot Milestone XProtect för kameraanrop.
Luftvy över ett distributions- och lagercenter med en inhägnad trailergård

Ladda ner fallstudien (PDF)

A distribution and fulfillment center hardened its 4,000 ft (1,200 m) perimeter with the IRONCLAD Fence Alarm System after repeated cargo theft attempts at the fence line. Four zones on two processors, installed by a security integrator in a few days without interrupting 24/7 yard operations, feeding Milestone XProtect so cameras turn to the alarmed zone automatically. Customer identity withheld at the client’s request.

Vilken typ av plats skyddades?

The customer operates a high-volume distribution and fulfillment center: a large warehouse ringed by loading docks, a trailer yard holding loaded and staged trailers, and truck lanes that run around the clock.

The perimeter is approximately 4,000 ft (1,200 m) of chain-link fence. Inside it sits exactly what organized cargo crime targets: loaded trailers waiting for dispatch, staged pallets at the docks, and high-value goods in predictable places at predictable times.

The site never stops. Trucks enter and leave through the night, dock doors cycle continuously, and any security measure that slowed the flow of outbound freight was ruled out from the start.

Vad var det som inte fungerade vid stängslet?

The operator was dealing with cargo theft attempts at the fence itself: intruders cutting through the chain-link to reach the trailer yard and staged freight, rather than coming through the gate.

That pattern is the hard one for conventional security. The gatehouse checks who drives in. Cameras record the yard. But a cut fence at the back of a 4,000 ft perimeter, at night, between patrol passes, gives an intruder minutes alone with loaded trailers before anyone is looking.

Each incident carried more than the value of what was taken: damaged fencing to repair, disrupted dispatch schedules, and claims paperwork for freight the operator was contractually responsible for.

Varför räckte inte kameror och patruller?

Both were already in place, and both are reactive. A camera records a theft that is already happening, and on a perimeter this size most camera views are of empty fence for hours at a time, which is exactly the footage nobody watches live. A patrol covers one point of the perimeter at a time.

The missing piece was detection at the boundary: something that reports the moment the fence is cut or climbed, and says where along 4,000 ft it happened, so the response starts while the intruder is still at the fence.

Vad installerades?

RBtec levererade IRONCLAD Perimeterskydd utomhus, a sensor cable mounted on the existing chain-link fence that detects the vibration signature of cutting, climbing and lifting at the fence fabric itself.

The deciding factor for a logistics site was noise discrimination. A distribution yard is one of the loudest vibration environments a fence sensor can operate in: heavy trucks passing within feet of the fence, dock machinery, and wind loading on long open runs. The system had to separate all of that from a person cutting the fence, or it would drown the operators in alerts and be ignored.

Hur driftsattes systemet?

The 4,000 ft perimeter was divided into four zones of approximately 1,000 ft (305 m), running on two LPU-402 processors with two zones each. Four zones means an alarm points the response to the right quarter of the perimeter rather than to the site in general.

A security integrator carried out the installation over a few days. The yard kept operating throughout: no gate closures, no suspended dock operations, no interruption to outbound freight. The sensor cable mounts to the existing fence as a single run, so there was no trenching and no new fence construction.

Commissioning is where a logistics site differs from a quiet one. Each zone was tuned to its own environment: the zone along the truck lane is set differently from the zone along the rear tree line, so heavy vehicle vibration in one place does not force reduced sensitivity everywhere. The processors sit in NEMA 4X, IP66 rated enclosures at the fence line.

Vad kopplar systemet till?

Alarms feed the site’s existing Milestone XProtect video management system. When a zone alarms, XProtect calls up the cameras covering that zone, so the operator sees the alarmed stretch of fence at the moment of the event instead of scrubbing footage afterwards.

This is the combination that makes a large perimeter workable: the sensor cable says something is happening and where, and the VMS puts eyes on it immediately. The guard force responds to a verified event at a known location, not to a bare siren.

Nothing new was added at the monitoring end. The site kept its XProtect installation, its cameras and its operating procedures; the fence became another input into a system the operators already used every shift.

Vad ändrades efter installationen?

The design intent is that detection now happens at the fence, before an intruder reaches the trailer yard or the docks, and that per-zone tuning keeps routine yard noise from reaching an operator as an alert. RBtec has not published measured before and after incident or alarm counts for this site.

Because the configuration is standard hardware in a standard pattern, the same design extends to other facilities in the operator’s network without re-engineering: count the fence length, divide by zone length, add processors.

On a logistics yard the tuning is the job. A truck passing three feet from the fence puts more energy into it than a person climbing it, so we set each zone to its own surroundings. The zone by the truck lane and the zone on the back line should never share one sensitivity setting.

RBtec:s teknikteam

Vad driftsattes

System IRONCLAD Perimeterskydd utomhus
Omkrets Approximately 4,000 ft (1,200 m)
Zoner Four zones of approximately 1,000 ft (305 m)
Processors Two LPU-402 units, two zones each
Staket täckning Single cable run per fence line, fences up to 10 ft (3 m)
Noise handling Per-zone tuning against heavy truck and loading dock vibration
Inhägnad NEMA 4X, IP66
Integration Milestone XProtect VMS, camera call-up to the alarmed zone
Installation Security integrator, a few days, yard operations uninterrupted
Garanti 2 years

Ladda ner fallstudien (PDF)

Vad är nästa steg?

If you operate a distribution center with a fenced yard, the two numbers that shape the design are total fence length and how many distinct noise environments the perimeter passes through: truck lanes, dock aprons, quiet rear lines. Send RBtec those two things and we will return a zone plan and processor count for the site.

RBtec Perimeter Security Systems har tillverkat intrångsdetekteringssystem för utomhusbruk sedan 1986 och har installerat över 5 000 system i 57 länder.

Dela:
Gillar du den här produkten?

Läs mer om det på produktsidan

Problem
Cargo theft attempts at the fence line, aimed at the trailer yard.
About 4,000 ft (1,200 m) of chain-link perimeter to watch around the clock.
Constant truck and yard activity that a detection system must not mistake for an intrusion.
Cuts in the fence found after the fact, with no alarm at the moment they happened.
Lösningar
IRONCLAD fence-mounted sensor cable across four zones of about 1,000 ft each, on two LPU-402 processors.
Integrated with the site’s Milestone XProtect VMS, so an alarm calls up the cameras on the alarmed zone.
Per-zone sensitivity tuning to separate cutting and climbing from vibration carried in by truck traffic.
Installed by the customer’s security integrator over a few days, with 24/7 yard operations uninterrupted.
Levererat värde
Covered sections of the logistics yard that previously had no detection at the fence line
Zone-level alarm location, so guards respond to the right stretch of fence instead of sweeping the whole perimeter.
An alarm raised at the fence line, before an intruder reaches the trailers and loading zones.
A hardened perimeter layer the operator can demonstrate in security audits.
A sensor cable that needs no routine recalibration and is built for the environmental wear of a 24/7 distribution site

Har Frågor?

Vi finns här för att hjälpa till. Oavsett om det är en snabb fråga eller något mer komplicerat: inget tryck, bara svar.

Denna anläggning delar upp cirka 4 000 ft (1 200 m) stängsel i fyra zoner på ungefär 1 000 ft vardera, som drivs av två IRONCLAD LPU-402-processorer. Varje LPU-402 stöder två zoner, så antalet processorer beror på stängslets omkretslängd: dela upp stängslet i zoner på upp till cirka 1 000 ft och räkna med en processor per två zoner.

Gårdstrafik är exakt vad driftsättning är till för. Varje zon har sina egna känslighetsinställningar, och processorn stäms in på plats för att skilja signaturen av kapning eller klättring från vibrationer som lastbils- och gaffeltruckrörelser för med sig in i staketet. Målet med den inställningen är att hålla obefogade larm nere medan gården fortsätter att vara i drift dygnet runt.

Ja. På den här anläggningen rapporterar varje zon till Milestone XProtect, så ett larm visar automatiskt kamerorna som täcker den larmande zonen och operatören ser stängslet i ögonblicket då händelsen inträffar. Samma utgångar ansluts till andra VMS-plattformar och larmpaneler via torra kontakter.

På den här platsen slutförde kundens säkerhetsintegratör installationen under några dagar medan anläggningen körde dygnet runt. Arbetet sker vid stängslet, zon för zon, utan grävning och utan avbrott för docknings- eller grindaktiviteter.

Verkliga resultat från Riktiga Kunder

Verkliga installationer, med problemet varje anläggning stod inför,
vad som installerades och hur det fungerar.

Skydda ditt område med RBtec

RBtec levererar innovativa lösningar för områdessäkerhet som åtnjuter förtroende över hela världen. Med över 5 000 installerade system i 57 länder kombinerar våra produkter tillförlitlighet, kostnadseffektivitet och användarvänlig design, oavsett anläggningens storlek eller risknivå.