Protección de bóvedas bancarias con sensores WallAlert

Un banco regional protegió las bóvedas de sus sucursales y el centro de procesamiento de efectivo con WallAlert: cable sensor en paredes y techos de bóvedas, una o dos zonas por sitio en un LPU-402, activado las 24 horas del día, los 7 días de la semana y reportando a través del panel de alarma existente, instalado en pocos días por sitio con sucursales abiertas.
Vista aérea de una sucursal bancaria suburbana con un carril de autoservicio y patio de servicio trasero seguro

Descarga el estudio de caso (PDF)

A regional commercial bank protected the vault rooms of its branches and its central cash-processing hub with WallAlert, RBtec’s wall intrusion detection system: sensor cable on the vault walls and ceiling, one to two zones per site on a single LPU-402 processor, armed around the clock and reporting through the bank’s existing alarm panel to its central station. A security integrator completed each site in a few days with branches operating as usual. Customer identity withheld at the client’s request.

¿Qué tipo de sitio se estaba protegiendo?

The customer is a regional commercial bank operating multiple high-traffic branches and a central cash-processing hub. Every site has a vault room, and every vault room already sits behind layers of security: access control, interior motion detection, cameras, and a monitored burglar alarm.

What those layers share is a blind side. They watch the inside of the secure area and the doors into it. None of them watch the walls.

The cash-processing hub sharpened the question. It concentrates more cash than any branch, it runs longer hours, and its vault shares structure with the rest of an ordinary commercial building. Whatever the bank chose had to work identically at a small branch and at the hub.

¿Qué riesgo existía en el muro de la bóveda?

Physical attacks on banks have shifted toward the building fabric: drilling or breaking through a vault wall from an adjacent tenancy, a neighboring basement, the roof, or the exterior of the building. An intruder working through the wall never crosses a door contact and never enters a motion sensor’s view until the wall is already open, and at that point the response clock starts far too late.

The bank wanted the clock to start at the other end of the attack: at the first minutes of drilling or cutting, while there is still a wall between the intruder and the cash.

¿Por qué no usar sensores de vibración convencionales?

Urban buildings are noisy structures. Traffic, passing trucks, construction nearby and the building’s own services all put vibration into the walls, and a sensor that cannot separate that background from a drill bit produces alarms nobody trusts. Point-type shock sensors also cover only the spot they are mounted on, which leaves the rest of a vault room’s surface area unwatched.

The bank needed continuous coverage across the whole surface of the vault envelope, with tuning against each site’s real background noise.

¿Qué se instaló?

Each site received WallAlert, RBtec’s wall-mounted sensor cable system. The cable runs across the vault room’s walls and ceiling and senses the structure-borne vibration of an attack on the fabric itself: drilling, cutting, hammering and breaking through concrete or brick.

A typical branch runs one or two zones on a single LPU-402 processor, which supports two zones of up to 1,000 ft (305 m) of sensor cable each, far more than a vault room needs, so a single processor covers the vault envelope with capacity to spare. Sensitivity is set per zone, tuned during commissioning against the branch’s own background: the street outside, the HVAC plant, the daily rhythm of the building.

¿Cómo se desplegó el sistema?

The bank’s security integrator installed the system site by site, taking a few days per branch. The work is confined to the vault room and the alarm panel, and the branches stayed open throughout: no closures, no interruption to teller operations, no change to opening hours.

Because the design repeats, the rollout across branches and the cash-processing hub was a pattern, not a series of custom projects: survey the vault room, run the cable, terminate at the processor, wire to the panel, tune.

¿A qué se conecta el sistema?

Each zone’s relay output lands on the bank’s existing burglar alarm panel as a dry contact, and travels the same path every other alarm at the branch travels: panel to central monitoring station. There is no new monitoring platform, no separate keypad and nothing new for branch staff to operate.

One choice matters here: the vault zones are armed around the clock, independent of branch opening hours. An attack on the wall is an alarm at 3 a.m. and at 11 a.m. alike, because a drill through a party wall does not wait for closing time.

¿Qué cambió después de la instalación?

The design intent is that an attack on the vault envelope raises an alarm at the drilling stage, while the wall still stands, giving the central station and police response time that interior sensors cannot give. RBtec has not published measured before and after alarm or incident counts for this bank.

The same cable and processor can extend to ATM rooms and night-deposit rooms where a branch’s risk assessment calls for it, on the same panel and the same monitoring path, so that extension stays open to the bank without any new infrastructure.

A vault is attacked from the side no camera can see. The sensor lives on the structure itself, so the alarm comes from the first minutes of drilling, not from the moment someone steps through the hole. And because it lands on the panel as a dry contact, nothing changed at the monitoring end.

Equipo de ingeniería de RBtec

¿Qué se desplegó?

Sistema Sistema de detección de intrusión en muros WallAlert
Cliente Regional commercial bank, multiple branches and a cash-processing hub
Cobertura Vault room walls and ceiling at each site
Zonas One to two zones per site, on one LPU-402 processor
Processor capacity LPU-402, two zones of up to 1,000 ft (305 m) of sensor cable each
Detecta Structure-borne vibration of drilling, cutting and breaking through walls
Arming Vault zones armed around the clock
Integración Dry contacts into the existing bank alarm panel, reporting to the central station
Instalación Security integrator, a few days per site, branches open throughout
Garantía 2 años

Descarga el estudio de caso (PDF)

¿Cuál es el siguiente paso?

For a bank or cash-handling operation, the design starts from a walk of the vault room: which walls are shared, what sits above and below, and where the panel is. Send RBtec a floor plan marking the vault and its neighbors, and we will return a cable layout, zone plan and panel integration notes your integrator can install from.

RBtec Perimeter Security Systems has built outdoor and structural intrusion detection since 1986, with more than 5,000 systems installed in 57 countries.

Compartir:
¿Te gusta este producto?

Más información en la página del producto.

Problema
Wall-breaching attacks that never cross a door contact or a motion sensor’s view.
Interior alarms that start the response clock only after the wall is open.
Urban vibration, traffic and construction that defeats simple shock sensors.
Branches and a cash hub needing one repeatable design.
Soluciones
Paredes y techo de la bóveda bancaria en cada sitio
One to two zones per site on a single LPU-402 processor.
Per-zone sensitivity tuned against each building’s own background noise.
Dry contacts into the existing alarm panel, reporting to the central station.
Valor entregado
The alarm starts at the drilling stage, while the wall still stands.
Vault zones armed around the clock, independent of branch hours.
Continuous coverage of the vault envelope, not a single point on it.
No new monitoring platform: alarms ride the panel path the bank already trusts.

¿Tiene preguntas?

Estamos aquí para ayudarle. Ya sea una pregunta rápida o algo más complejo: sin presiones, solo respuestas.

Esa separación es para lo que sirve la puesta en marcha. Cada zona tiene su propia configuración de sensibilidad, calibrada según el ruido de fondo real del sitio: el tráfico de la calle, la planta de HVAC, el ritmo diario del edificio. Un ataque a la estructura de la pared, perforar, cortar, martillar, conlleva una firma transmitida por la estructura diferente a la vibración ambiental de la ciudad, y el objetivo de la calibración es mantener bajas las falsas alarmas mientras la pared sigue vigilada.

No. Cada zona de WallAlert se conecta al panel de alarma contra robos existente del banco como un contacto seco y recorre la misma ruta que cualquier otra alarma en la sucursal: del panel a la estación central de monitoreo. No hay una nueva plataforma, ni un teclado separado, ni nada nuevo para que opere el personal de la sucursal.

Sí. En este banco las zonas de la bóveda están armadas las 24 horas, independientemente de los horarios de apertura de la sucursal. Un ataque a través de una pared medianera o desde un espacio vecino no espera al horario de cierre, por lo que la cobertura de la pared tampoco.

One LPU-402 processor supports two zones with up to 1,000 ft (305 m) of sensor cable each, which is far more than a vault room needs. A typical branch runs one or two zones on a single processor, with capacity to spare for extending coverage to ATM or night-deposit rooms.

Resultados reales de clientes reales

Instalaciones reales que muestran el problema de cada sitio,
qué se instaló y cómo funciona.

Proteja sus instalaciones con RBtec

RBtec ofrece soluciones de seguridad perimetral utilizadas en todo el mundo. Con más de 5,000 sistemas instalados en 57 países, nuestros productos combinan confiabilidad, rentabilidad y facilidad de uso para instalaciones de distintos tamaños y niveles de riesgo.