Bankschließfachschutz mit WallAlert-Sensoren

Eine Regionalbank sicherte die Tresorräume ihrer Filialen und ihres Bargeldverarbeitungszentrums mit WallAlert ab: Sensorkabel an den Wänden und Decken der Tresorräume, ein bis zwei Zonen pro Standort an einer LPU-402, rund um die Uhr scharfgeschaltet und Meldung über die vorhandene Alarmzentrale, Installation innerhalb weniger Tage pro Standort bei laufendem Filialbetrieb.
Luftaufnahme einer Vorstadtbankfiliale mit einer Fahrspur und einem gesicherten hinteren Servicehof

Laden Sie die Fallstudie (PDF) herunter

A regional commercial bank protected the vault rooms of its branches and its central cash-processing hub with WallAlert, RBtec’s wall intrusion detection system: sensor cable on the vault walls and ceiling, one to two zones per site on a single LPU-402 processor, armed around the clock and reporting through the bank’s existing alarm panel to its central station. A security integrator completed each site in a few days with branches operating as usual. Customer identity withheld at the client’s request.

Welche Art von Gelände wurde geschützt?

The customer is a regional commercial bank operating multiple high-traffic branches and a central cash-processing hub. Every site has a vault room, and every vault room already sits behind layers of security: access control, interior motion detection, cameras, and a monitored burglar alarm.

What those layers share is a blind side. They watch the inside of the secure area and the doors into it. None of them watch the walls.

The cash-processing hub sharpened the question. It concentrates more cash than any branch, it runs longer hours, and its vault shares structure with the rest of an ordinary commercial building. Whatever the bank chose had to work identically at a small branch and at the hub.

What was the gap at the vault wall?

Physical attacks on banks have shifted toward the building fabric: drilling or breaking through a vault wall from an adjacent tenancy, a neighboring basement, the roof, or the exterior of the building. An intruder working through the wall never crosses a door contact and never enters a motion sensor’s view until the wall is already open, and at that point the response clock starts far too late.

The bank wanted the clock to start at the other end of the attack: at the first minutes of drilling or cutting, while there is still a wall between the intruder and the cash.

Why not standard vibration sensors?

Urban buildings are noisy structures. Traffic, passing trucks, construction nearby and the building’s own services all put vibration into the walls, and a sensor that cannot separate that background from a drill bit produces alarms nobody trusts. Point-type shock sensors also cover only the spot they are mounted on, which leaves the rest of a vault room’s surface area unwatched.

The bank needed continuous coverage across the whole surface of the vault envelope, with tuning against each site’s real background noise.

Was wurde installiert?

Each site received WallAlert, RBtec’s wall-mounted sensor cable system. The cable runs across the vault room’s walls and ceiling and senses the structure-borne vibration of an attack on the fabric itself: drilling, cutting, hammering and breaking through concrete or brick.

A typical branch runs one or two zones on a single LPU-402 processor, which supports two zones of up to 1,000 ft (305 m) of sensor cable each, far more than a vault room needs, so a single processor covers the vault envelope with capacity to spare. Sensitivity is set per zone, tuned during commissioning against the branch’s own background: the street outside, the HVAC plant, the daily rhythm of the building.

Wie wurde das System bereitgestellt?

The bank’s security integrator installed the system site by site, taking a few days per branch. The work is confined to the vault room and the alarm panel, and the branches stayed open throughout: no closures, no interruption to teller operations, no change to opening hours.

Because the design repeats, the rollout across branches and the cash-processing hub was a pattern, not a series of custom projects: survey the vault room, run the cable, terminate at the processor, wire to the panel, tune.

Womit verbindet sich das System?

Each zone’s relay output lands on the bank’s existing burglar alarm panel as a dry contact, and travels the same path every other alarm at the branch travels: panel to central monitoring station. There is no new monitoring platform, no separate keypad and nothing new for branch staff to operate.

One choice matters here: the vault zones are armed around the clock, independent of branch opening hours. An attack on the wall is an alarm at 3 a.m. and at 11 a.m. alike, because a drill through a party wall does not wait for closing time.

Was hat sich nach der Installation geändert?

The design intent is that an attack on the vault envelope raises an alarm at the drilling stage, while the wall still stands, giving the central station and police response time that interior sensors cannot give. RBtec has not published measured before and after alarm or incident counts for this bank.

The same cable and processor can extend to ATM rooms and night-deposit rooms where a branch’s risk assessment calls for it, on the same panel and the same monitoring path, so that extension stays open to the bank without any new infrastructure.

A vault is attacked from the side no camera can see. The sensor lives on the structure itself, so the alarm comes from the first minutes of drilling, not from the moment someone steps through the hole. And because it lands on the panel as a dry contact, nothing changed at the monitoring end.

Das RBtec-Entwicklungsteam

Was wurde eingesetzt

System WallAlert wall intrusion detection
Kunde Regional commercial bank, multiple branches and a cash-processing hub
Abdeckung Vault room walls and ceiling at each site
Zonen One to two zones per site, on one LPU-402 processor
Processor capacity LPU-402, two zones of up to 1,000 ft (305 m) of sensor cable each
Detects Structure-borne vibration of drilling, cutting and breaking through walls
Arming Vault zones armed around the clock
Integration Dry contacts into the existing bank alarm panel, reporting to the central station
Installation Security integrator, a few days per site, branches open throughout
Garantie 2 Jahre

Laden Sie die Fallstudie (PDF) herunter

Was ist der nächste Schritt?

For a bank or cash-handling operation, the design starts from a walk of the vault room: which walls are shared, what sits above and below, and where the panel is. Send RBtec a floor plan marking the vault and its neighbors, and we will return a cable layout, zone plan and panel integration notes your integrator can install from.

RBtec Perimeter Security Systems has built outdoor and structural intrusion detection since 1986, with more than 5,000 systems installed in 57 countries.

Teilen:
Gefällt dir dieses Produkt?

Erfahren Sie mehr auf der Produktseite

Problem
Wall-breaching attacks that never cross a door contact or a motion sensor’s view.
Interior alarms that start the response clock only after the wall is open.
Urban vibration, traffic and construction that defeats simple shock sensors.
Branches and a cash hub needing one repeatable design.
Lösungen
WallAlert sensor cable across the vault room’s walls and ceiling at every site.
One to two zones per site on a single LPU-402 processor.
Per-zone sensitivity tuned against each building’s own background noise.
Dry contacts into the existing alarm panel, reporting to the central station.
Geschaffener Mehrwert
The alarm starts at the drilling stage, while the wall still stands.
Vault zones armed around the clock, independent of branch hours.
Continuous coverage of the vault envelope, not a single point on it.
No new monitoring platform: alarms ride the panel path the bank already trusts.

Haben Fragen?

Wir sind für Sie da. Ob es sich um eine kurze Frage oder um ein komplexeres Anliegen handelt: Kein Druck, nur Antworten.

Genau dieser Trennung dient die Inbetriebsetzung. Jede Zone verfügt über eigene Empfindlichkeitseinstellungen, die auf den tatsächlichen Untergrund des Standorts abgestimmt sind: Straßenverkehr, HLK-Anlagen, den täglichen Rhythmus des Gebäudes. Ein Angriff auf die Wandstruktur, Bohren, Schneiden, Hämmern weist eine andere körperschallgebundene Signatur auf als die Umgebungsvibration der Stadt, und das Ziel der Abstimmung ist es, Fehlalarme gering zu halten, während die Wand überwacht bleibt.

Nein. Jede WallAlert-Zone wird als potentialfreier Kontakt auf die bestehende Einbruchmeldezentrale der Bank geschaltet und nimmt denselben Weg wie jeder andere Alarm in der Filiale: von der Zentrale zur Notruf- und Serviceleitstelle. Es gibt keine neue Plattform, kein separates Bedienteil und nichts Neues, das das Filialpersonal bedienen müsste.

Ja. Bei dieser Bank sind die Tresorzonen rund um die Uhr scharf geschaltet, unabhängig von den Öffnungszeiten der Filiale. Ein Angriff durch eine Brandwand oder von einem Nachbarraum aus wartet schließlich auch nicht bis zum Feierabend, also wartet die Wandüberwachung das ebenfalls nicht ab.

Ein LPU-402-Prozessor unterstützt zwei Zonen mit jeweils bis zu 305 m (1.000 Fuß) Sensorkabel, was weit mehr ist, als ein Tresorraum benötigt. Eine typische Filiale betreibt ein oder zwei Zonen auf einem einzigen Prozessor, mit Kapazitätsreserven für die Ausweitung der Überwachung auf Geldautomaten- oder Nachttresorräume.

Echte Ergebnisse aus Echte Kunden

Reale Installationen — mit dem Problem, vor dem jeder Standort stand,
was installiert wurde und wie es sich bewährt.

Schützen Sie Ihr Gelände mit RBtec

RBtec bietet innovative Lösungen für die Perimetersicherheit, denen weltweit Vertrauen entgegengebracht wird. Mit über 5.000 installierten Systemen in 57 Ländern vereinen unsere Produkte Zuverlässigkeit, Wirtschaftlichkeit und benutzerfreundliches Design – unabhängig von der Größe des Standorts oder dem Risikograd.